The LT Series RTU is a dedicated controller product developed by Hollysys for remote intelligent control of oil pumping units in oil and gas extraction. It is widely used in oilfield companies such as Daqing, Liaohe, Xinjiang, Tuha, and Changqing. The LT Series RTU intelligent measurement and control terminal adopts a domestic ARM processor combined with embedded software developed based on the Linux open-source operating system, achieving 100% independent controllability. It is widely applied in scenarios such as single-well and regional well site production intellectualization. The product is designed in accordance with "GB/T 34039-2017 Technical Specifications for Remote Terminal Units (RTU)" and PetroChina's "Specifications for Construction of Oil and Gas Production Internet of Things System". It features high-performance computing capabilities and abundant data acquisition, communication, and control interfaces, enabling rapid integration of various measurement and control terminal devices and sensing equipment as well as implementation of intelligent applications
Function | Model |
LT-CU-102 | |
Module Structure | Integrated |
Power Supply | 220V AC ±30% / 24V DC Static power consumption: 3W |
Processor | 32-bit ARM9 Processor, Embedded LINUX Operating System, 300MHz |
Integrated Storage Memory | 64MB SDRAM |
Persistent Memory Space | 256MB FLASH |
DI (Digital Input) | 4 |
DO (Digital Output) | 4 |
AI (Analog Input) | 4 |
AO (Analog Output) | 4 |
Module Expansion | Built-in 4AI + 4AO Expansion Card |
RS485 Interface | 2 Channels |
RS485 Communication Protocol and Mode | Modbus RTU/ASCII |
RS232 Interface | 2 Channels |
RS232 Communication Protocol and Mode | Modbus RTU/ASCII |
Ethernet RJ45 | 2 Channels |
Ethernet Communication Protocol and Mode | Modbus TCP |
Supports Dual Network Redundancy | Supports Dual Network Segment Redundancy |
Wireless Networking | 4G, Zigbee, Integrated WiFi Chip, LoRa |
USB | 1 Channel |
Operating Temperature | -40ºC ~ +80ºC |
Normal Operating Humidity (%) | 5% - 95%, Non-condensing |
Operating Altitude | ≤ 3000m |
Electrical Parameters | Integrated Electrical Parameter Acquisition for 1 Well |
Screen | Integrated 320*240 Dot Matrix LCD Screen |
Module Dimensions (Width * Height * Depth) | 164*212*50mm |
Mounting Method | Standard DIN Rail |
Intermittent Pumping Function | Dry Pumping Control, Intermittent Pumping Control, Automatic Startup on Power-on, Continuous Spraying and Pumping Control, Peak-valley Electricity Saving Control |
Remote Firmware Upgrade | Remote Upgrade for the Main Unit and Connected Sensors |