Customization: | Available |
---|---|
Function: | Automatic Control, Protection, Monitoring, Measurement |
Certification: | CE |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Series XD 3 E- | 24R/T | 30R/T | 48R/T | 60R/T | ||||
noumenon I/O | Total number of points | 24 | 30 | 48 | 60 | |||
Number of input points | l4 | 16 | 28 | 36 | ||||
Number of output points | 10 | l4 | 20 | 24 | ||||
Maximum number of I / O points | 536 | 542 | 560 | 572 | ||||
High speed positioning | Ordinary pulse output | 2 Axis | 2 Axis | 2 Axis | 2 Axis | |||
Differential pulse output | ||||||||
High-speed input | Single-phase / AB mode | 3 Road | 3 Road | 3 Road | 3 Road | |||
input pattern | OC | OC | OC | OC | ||||
Expanded ability | Right extension module | |||||||
Left extension module | ||||||||
BD board | 2 | 2 | ||||||
suspend | external interrupt | |||||||
timer interruption | 20 | |||||||
Other interruptions | High-speed count interruption, pulse interruption | |||||||
Communication function | Communication mouth | 1 RS232,1485,2 Ethernet | ||||||
protocol | Standard MODBUS ASCIl / RTU communication, free-format communication | |||||||
Bus function | The X-NET fieldbus | |||||||
PWM pulse-width modulation | support | |||||||
frequency measurement | 3 Road | |||||||
Accurate timing | support | |||||||
Multi-station control | ||||||||
How the program is executed | Cycle scanning mode | |||||||
Programming method | LD , ST, C , I L | |||||||
Power failure to maintain | make use of F | ashROM And lithium battery (3V button battery) | ||||||
Basic instruction processing speed | 0 . 02 ~ 0 . 05US | |||||||